JOEO Walk In Salt Spray Chamber is different from basic salt spray test chamber.Walk In Salt Spray Chamber exposes sample to a series of different environments in repetitive cycles that incorporate temperature , humidity, salt spray and dry.
Accelerated corrosion test methods included ASTM B117, ASTM BG85, ISO9227, IEC60068-2-52, iec61701-2, ISO7253 and many others.
Model | Temp&Humidity Salt Spray Chamber |
W-STH-4000 | W-STH-5000 | W-STH-8000 | W-STH-10000 | W-STH-12000 | Customize |
Internal Dimension WxHxD (mm) | 1500x1800x1400 | 1700x1800x1600 | 2000x2000x2000 | 2600x2000x2200 | 2000x2000x3000 | ||
External Dimension WxHxD (mm) | 1600x2850x2380 | 1800x2850x2580 | 2200x3050x2980 | 2800x3050x3180 | 2200x3050x4980 | ||
Capacity (L) | 3780 | 5000 | 8000 | 11,500 | 12,000 | ||
Test Standard | ACSS, SOAK , DRYAIR , HUMI, ROOMAIR | ||||||
Temperature Range | A: RT (+15 ℃) ~ +85℃ B: -10℃ ~ +85℃ C:-20℃ ~ +85℃ D:-40℃ ~ +85℃ E:-55℃ ~ +85℃ | ||||||
Humidity Range | 20% ~98% R.H ,15%~95% R.H add dehumidifier or Dryer | ||||||
Temperature Rising/ Falling Speed Rate |
Temperature rising approx:0.1~ 3.0℃/min( 3-10℃/min whole Course Average-optional) Temperature falling approx:0.3-1.0℃/min ( 3-10℃/min whole Course Average-optional) |
||||||
Analytic Accuracy/ Distribution Uniformity of Temp & Humidity |
0.1℃ ; 0.1% R.H ±2.0℃ ; ±5% R.H |
||||||
Control Accuracy of Temperature | ±0.5℃ ±2.5℃ 2%R.H |
||||||
Pressure Bucket Temperature | Saline test method (NSS ACSS) 47±1℃; Corrosion Test (CASS)63±1℃ | ||||||
Compressed Air Pressure (KGf) | 1.0-6.0 | ||||||
Spray Volume | 1.0-2.0ml/80cm²/h (working at least 16 hours, and take the average value) | ||||||
Compressor | French "Tecumseh" Brand, Germany "Bitzer" Brand or samilar brand | ||||||
Optional Accessories | Sample shelf , Cart etc | ||||||
Spray Method | Continuous spray or Programmable spray | ||||||
Power | AC220V,1phase3 lines 50/60Hz AC380V,3 phase 5 lines 50/60Hz |