HALT Test Chamber 's Halt test is a process that uses a oscillating system of rapid high and low temperature changes to reveal design flaws and deficiencies in electronic and mechanical assemblies.
Thereby increasing product reliability.
Improved product life can also be accomplished using HALT.
Model | HALT & HASS Chambers |
2HLS-210 | 2HLS-430 | 2HLS-760 | 2HLS-1100 | |
Internal Dimension (WxHxD mm) |
610x580x610 | 760x760x760 | 914x914x914 | 1070x965x1070 | ||
External Dimension (WxHxD mm) |
1570x2030x910 | 1570x2030x1060 | 1730x2185x1214 | 1886x2440x1370 | ||
Temperature Range | -100 to +200℃ | |||||
Heating &Cooling Rate(average) | 70℃/min (Supprot customize if have special requirement) |
|||||
Vibration Table Dimension(mm) | 510x510 | 610x610 | 760x760 | 910x910 | ||
Vibration Frenquecy Range(Hz) | 5-5000Hz | |||||
Vibration Acceleration (GMS) | 5-60GMS | |||||
Vibration overshoot | ≦2GMS | |||||
Max.Load (kg) | 55 | 70 | 95 | 150 | ||
Actuators(pcs) | 6 | 6 | 9 | 13 | ||
Liquid Nitrogen Consumptiom |
25~60L/min (Liquid Nitrogen Pressure at 2.8~3.5 Bar |
|||||
Compressed Air Consumption |
400L/min | 990L/min | 1130L/min | 1950L/min | ||
Air pressure at 7Bar | ||||||
Windows(pcs) | 1 | 2 | 2 | 2 | ||
Viewing window Dimension (WxD mm) |
300x300 | 300x360 | 380x480 | 380x520 | ||
Door(pcs) | 1 | 2 | 2 | 2 | ||
Vibration Monitoring | Two vibration channels for users with real-time monitoring of product vibration. The analysis of acceleration response spectrum |
|||||
Power supply | AC380V 3phase 5lines 50/60Hz | |||||
Ectrical Service | Power (KW) | 27 | 48 | 64 | 83 | |
Current(A) | 50 | 86 | 150 | 175 | ||
Weight(kg) | 420 | 860 | 1133 | 1814 |