IEC 68-2-13 is a standard for environmental testing developed by the International Electrotechnical Commission (IEC), which specifically specifies the methods of testing under temperature change conditions. This standard is part of the IEC 68-2 series of environmental test standards, aiming to evaluate the performance and reliability of products under different temperature conditions

5 Test procedures 

5.1 Severities 

5.1.1 General 

The test severities, in terms of air pressure and duration of exposure, shall be specified in the relevant specification. The values of air pressure should preferably be selected from those given in 5.1.2 and 5.1.3. 

5.1.2 Air pressure 

The test air pressure shall be specified in the relevant specification and should preferably be selected from Table 1. Further air pressure values according to standard atmosphere, are found in ISO2533.


5.1.3 Duration of exposure 

The test duration shall be specified in the relevant specification and should preferably be selected from one of the following durations. Guidance on selecting an appropriate duration is provided in Annex A. 

-5 min; 

-30 min; 

-2 h; 

-4 h; 

-16 h.


5.3 Initial measurements 

The specimen shall be visually inspected and electrically and mechanically checked as required by the relevant specification. 

5.4 Conditioning 

It shall be possible to maintain the air pressures in Table 1, or as specified in the relevant specification, in the chamber with a tolerance of ±5 % or ±0,1 kPa whichever is the larger. The tolerance on the 84 kPa severity shall be ±2 kPa. 

At the start and throughout the test, the test chamber shall be within the required temperature range specified by the standard atmospheric conditions for testing according to IEC 60068-1. 

The specimen shall be introduced into the chamber in an orientation, configuration and operational state as specified in the relevant specification. 

The pressure within the chamber shall then be reduced to the value appropriate to the severity. The relevant specification may limit the rate of change of pressure to not more than 15 kPa/min when considered necessary.

 If required by the relevant specification, the specimen shall be operated and/or function inl accordance with the procedures set out in the relevant specification. For heat-dissipatingl specimens, the relevant specification may require the specimen temperature to be stabilized before any functional checks and/or measurements are made. 

If required by the relevant specification, intermediate measurements shall be performed. 

The air pressure shall be maintained for the specified duration. The air pressure shall be restored to normal. If required by the relevant specification, the rate of change of air pressure shall not exceed 15 kPa/min.


The TEST EQ environmental chamber strictly adheres to IEC 68-2-13 international standard, providing ±0.5 ° C temperature control accuracy and 10%-98%RH wide range humidity regulation capability, which can simulate extreme environments to verify the durability of electronic products. With our equipment, you can quickly obtain the compliance reports required for ISO/IEC certification and shorten the R&D cycle by 30%. Click to get a free test plan → (with real laboratory videos + cooperation cases with Fortune 500 companies)


  • Add: TESTEQ Science and Technology Park, No. 5, Wenzhou Road, Dongcheng Sub-district, Dongguan City, Guangdong Province, China

    Whatsapp(Phone): +8613310826672

    Tel: +86-0769-85914911

    Web: www.chamber-testing.com

    E-mail: Kris@test-eq.com

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with
the suffix "@test-eq.com".

We will contact you within 1 working day, please pay attention to the email with the suffix "@test-eq.com".

Company
Name*
Phone
E-Mail*
Nation
Message
By selecting the ‘I agree’ button, you consent to the processing of your personal data for marketing purposes and for the sending of commercial information by TESTEQ Company through telephone, e-mail, newsletters, text messages such as sms, chat and social networks.
I AGREE
By submitting your personal data, you declare that you have read the Privacy Policy of the website.

P.IVA: 91441900MAECQJHY37 Guangdong TESTEQ Testing Equipment Co., LTD | All Rights Reserved