Contact Us: +8613310826672 / [email protected]
JOEO factory supply a variety of environmental chambers for testing small battery cells to large lithium ion battery packs. Battery test chambers are supplied to a variety of industries including telecommunications, computer and automotive.
Each humidity control chamber is built according to specific test requirements and may be interfaced with battery cyclers, control & monitoring data acquisitions systems and other test equipment for a complete integrated test solution.
With the goal of reducing automobile emissions and the development of electric vehicles, the need for lithium ion battery test is even more critical.
Our proven experience provides the most cost-effective solutions.
Hazard Severity Level |
Description | Classification Criteria and Effect |
0 | No Effect | No effect. No loss of functionality |
1 | Passive Protection Activated | No defect; no leakage; no venting, fire, or flame;no rupture;no explosion;no exothermic reaction or thermal runaway. Cell reversibly damaged.Repair of protection device needed. |
2 | Defect/Damage | No leakage; no venting, fire, or flame; no rupture; no explosion;no exothermic reaction or thermal runaway.Cell irreversibly damaged.Repair needed. |
3 | Minor Leakage | No venting, fire, or flame*; no rupture;no explosion. Weight loss |
4 | Major Leakage/ Venting | No fire or flame; no rupture; no explosion.Weight loss ≥50% of electrolyte weight(electrolyte = solvent + salt). |
5 | Fire or Flame | No rupture; no explosion (i.e., no flying parts). |
6 | Rupture | No explosion, but flying parts of the active mass |
7 | Explosion | Explosion (i.e., disintegration of the cell). |
Parameters
Model |
Environmental Test |
THC-80(A-F) |
THC-150(A-F) |
THC-225(A-F) |
THC-408(A-F) |
THC-800(A-F) |
THC-1000(A-F) |
Internal Dimension (WxHxD mm) |
400x500x400 |
500x600x500 |
600x750x500 |
600x850x800 |
1000x1000x800 |
1000x1000x1000 |
|
External Dimension (WxHxD mm) |
950x1450x1000 |
1050x1550x1050 |
1150x1900x1050 |
1200x1950x1350 |
1550x2000x1350 |
1550x2000x1550 |
|
Humidity Range |
20% ~98%R.H. |
||||||
Temperature Range |
Low Temperature : (A: 25℃; B: 0℃; C: -20℃; D: -40℃; E: -60℃; F:-70℃) |
||||||
Temperature Rising/ |
Temperature rising approx:0.1~ 3.0℃/min; |
||||||
Analytic Accuracy/ |
0.1℃ ; 0.1% R.H |
||||||
Control Accuracy/fluctuation of |
±0.5℃ ; ±2.0% R.H |
||||||
Optional Accessories |
Inner door with operation Hole , Recorder, Water Purifier, Dehumidifier,Dryer etc |
||||||
Compressor |
French "Tecumseh" Brand, Germany "Bitzer" Brand or samilar brand |
||||||
Power |
AC220V; 1phase 3 lines ; 50/60HZ |
||||||
Approx. Weight (Kg) |
150 |
180 |
250 |
380 |
560 |
700 |
Specification | Description |
ANSI C18.3M, Part 2 | Portable Lithium Primary Cells and Batteries - Safety Standard |
IEC 60086-4 | Primary Batteries – Safety of Lithium Batteries |
IEC 61960 | Secondary Lithium Cells and Batteries for Portable Applications |
IEC 62133 | Portable Sealed Secondary Cells and for Batteries made from them, for use in Portable Applications |
IEC 62281 | Safety of primary and secondary lithium cells and batteries during transport (similar to UN/DOT 38.3) |
IEC 62660-2 | Secondary lithium-ion cells for the propulsion of electric road vehicles – part 2: reliability |
IEEE 1725 | Rechargeable Batteries for Cellular Telephones |
IEEE 1625 | Rechargeable Batteries for Multi-Cell Mobile Computing Devices |
RTCA DO-311 | Minimum Operational Performance Standards for Rechargeable Lithium Battery Systems |
SAE J 2929 | Electric and Hybrid Vehicle Propulsion Battery System Safety Standard - Lithium -Based Rechargeable Cells |
SAE J 2289 | Electric Drive Battery Pack System Functional Guidelines |
SAE J 2464 | Electric and Hybrid Electric Vehicle Rechargeable Energy Storage System (RESS) Safety and Abuse Testing |
UN/DOT 38.3 | Covers transportation safety testing for all lithium metal and lithium ion cells and batteries |
UL 1642 | Used for testing lithium cells. Battery level tests are covered by UL 2054 |
UL 2054 | Household and Commercial Batteries - Component cell level testing covered by UL 1642 |
UL 2580 | Batteries for use in Electric Vehicles |
UL 2054 | Household and Commercial Batteries - Component cell level testing covered by UL 1642 |
UN/DOT 38.3 | Covers transportation safety testing for all lithium metal and lithium ion cells and batteries |
USCAR | Battery safety and performance from the EV Battery Test Procedures Manual, Battery Technology Life Verification Test Manual |