High Altitude Chamber(altitude simulation chamber)

High Altitude Chamber(altitude simulation chamber)

JOEO factory altitude simulation chamber is designed to allow users to perform temperature, humidity, and altitude condition tests in a combined test chamber, and create multiple conditions to meet multiple test requirements at the same time. 
Designed to simulate altitude conditions up to 100,000 feet. 
Provides simultaneous temperature/altitude testing from site altitude to 65,000 feet for high altitude test chamber testing. 
Humidity test can only be performed at the altitude of the site. 
Heated inspection window to ensure that the test room is clearly visible.

Description

Feature

High Altitude Chamber Testing of avionics or other aerospace equipment to simulate actual conditions it might experience.
Simulation of high-altitude conditions like might be found in mountainous regions.
High altitude chamber are used for autom otivetests to simulate mountainous conditions and totest computers, electronics and packaging materials that may be shipped via airfreight. It is especially important for defense and aerospace applications where pressure and vacuum conditions are even more intense. These chambers are JOEO company's most classic test chamber. JOEO (temperature/altitude) and ACC-Series (temperature/altitude/humidity) chambers are designed to allow the userto perform temperature, humidity. and altitude condition testing in one combined test chamber More than one condition can be created simultaneously to satisfy many types of test requirements.

 

Programmer Touch-screen Controller

  1. With a brilliant 7"color touch screen display, the powerful 1500 Programmer Controller is ALI Test Equipment ready, making operations and data collection easier and more reliable than ever before. Our controller has a Windows look and feel to support familiar and robust operations. The 1500 is ethernet-compatible and web-enabled with an Internet-ready front end for virtual anytime/anywhere access. Multi-level, password-based security prote cts sensitive data. The 1500 can be easily retrofitted on-site to existing chambers.

  2. Run mode :Program mode, fixed value mode

  3. Program capacity :Edit: up to 20 programs, up to 50 steps per program, 20 loops can be set(Each lo op step has up to 999 times of loop)

  4. Display resolution :Temperature: 0.1℃; time: 0.1 minute; Humidity: 0.1%RH;Altitude:10Pa

  5. Communication function :RS-485 interface, which has local and remote communication functions (it is required to fit centralized monitoring software, RS485/RS232 converter, it will occupy a COM port and a USB port of PC machine); up to 16 device s can be connected, the cumulative length of cable is up to 800m.

  6. Failure alarm and reason, dispose prompt function; power failure protection function; upper & lower limits of temperature prote ction function; timing function (auto start and auto stop running), self-diagnostic function.requirements.

Parameters 

Model

Temperature Low
Pressure Test Chamber

ACC-125

ACC-512

ACC-800

ACC-1000

ACC-2160

ACC-9000

Size

Internal Dimension WxHxD (mm)

500x500x500

800x800x800

1000x1000x800

1000x1000x1000

1800x1000x1200

1730x1980x2600

External Dimension WxHxD (mm)

900x1680x1750

1200x1880x2050

1400x2080x2050

1400x2180x2250

2200x2180x2570

2130x2440x4673

Volume (L)

125L

512L

800L

1000L

2160L

8900L

Pressure

Pressure range

             Normal pressure~0.5Kpa ( 500pa)

Pressure error

             Ordinary pressure~40kpa≦±2kpa;
             40kPa~4kPa≦±5kPa;
             4kPA~1kPa≦±0.1kpa

Depressurization time

             From site level to 15250m in 10minutes
             From site level to  22860m in 20minutes
             From site level to 30500m in 30minutes

Rapid decompression time

             75.2kPa~18.8kPa≦15s (Optional)

Explosive decompression time

             75.2kPa~18.8kPa≦0.1s (Optional)

Temperature

Temperature range

             Low temperature range: A:0℃; B: -20℃; C:-40℃; D:-70℃
             High temperature range: 150℃(180℃ is Optional)

Temperature fluctuation

             ±0.5℃

Temperature Rising/
Falling Speed Rate

             Temperature rising approx:0.1~ 2.0℃/min;
             Temperature falling approx:0.3-1.0℃/min

Temperature uniformity

             ±1.5℃(-40.0℃∽100.0℃)

             ±2.0℃(100.1℃~180.0℃or-40.0℃∽-70.0℃)

Humidity

Humidity range

             20%RH~98%RH(work under atmos pheric humidity)
             10%R.H ~98%R.H (Optional)

Humidity fluctuation

             ±2.0%RH

Humidity uniformity

             ≦±3.0%RH(humidity >75%R.H)
             ≦±5.0%RH(humidity ≦75%R.H)

Power

             AC380V 3phase 5lines  50/60Hz

Aprroximate weight(kg)

570

1000

1200

1300

2500

7500

Marked

             Other dimensions accept customize,
             details parameter need contact with Sales team