JOEO factory altitude simulation chamber is designed to allow users to perform temperature, humidity, and altitude condition tests in a combined test chamber, and create multiple conditions to meet multiple test requirements at the same time.
Designed to simulate altitude conditions up to 100,000 feet.
Provides simultaneous temperature/altitude testing from site altitude to 65,000 feet for high altitude test chamber testing.
Humidity test can only be performed at the altitude of the site.
Heated inspection window to ensure that the test room is clearly visible.
Feature
High Altitude Chamber Testing of avionics or other aerospace equipment to simulate actual conditions it might experience.
Simulation of high-altitude conditions like might be found in mountainous regions.
High altitude chamber are used for autom otivetests to simulate mountainous conditions and totest computers, electronics and packaging materials that may be shipped via airfreight. It is especially important for defense and aerospace applications where pressure and vacuum conditions are even more intense. These chambers are JOEO company's most classic test chamber. JOEO (temperature/altitude) and ACC-Series (temperature/altitude/humidity) chambers are designed to allow the userto perform temperature, humidity. and altitude condition testing in one combined test chamber More than one condition can be created simultaneously to satisfy many types of test requirements.
Programmer Touch-screen Controller
With a brilliant 7"color touch screen display, the powerful 1500 Programmer Controller is ALI Test Equipment ready, making operations and data collection easier and more reliable than ever before. Our controller has a Windows look and feel to support familiar and robust operations. The 1500 is ethernet-compatible and web-enabled with an Internet-ready front end for virtual anytime/anywhere access. Multi-level, password-based security prote cts sensitive data. The 1500 can be easily retrofitted on-site to existing chambers.
Run mode :Program mode, fixed value mode
Program capacity :Edit: up to 20 programs, up to 50 steps per program, 20 loops can be set(Each lo op step has up to 999 times of loop)
Display resolution :Temperature: 0.1℃; time: 0.1 minute; Humidity: 0.1%RH;Altitude:10Pa
Communication function :RS-485 interface, which has local and remote communication functions (it is required to fit centralized monitoring software, RS485/RS232 converter, it will occupy a COM port and a USB port of PC machine); up to 16 device s can be connected, the cumulative length of cable is up to 800m.
Failure alarm and reason, dispose prompt function; power failure protection function; upper & lower limits of temperature prote ction function; timing function (auto start and auto stop running), self-diagnostic function.requirements.
Parameters
Model |
Temperature Low |
ACC-125 |
ACC-512 |
ACC-800 |
ACC-1000 |
ACC-2160 |
ACC-9000 |
Size |
Internal Dimension WxHxD (mm) |
500x500x500 |
800x800x800 |
1000x1000x800 |
1000x1000x1000 |
1800x1000x1200 |
1730x1980x2600 |
External Dimension WxHxD (mm) |
900x1680x1750 |
1200x1880x2050 |
1400x2080x2050 |
1400x2180x2250 |
2200x2180x2570 |
2130x2440x4673 |
|
Volume (L) |
125L |
512L |
800L |
1000L |
2160L |
8900L |
|
Pressure |
Pressure range |
Normal pressure~0.5Kpa ( 500pa) |
|||||
Pressure error |
Ordinary pressure~40kpa≦±2kpa; |
||||||
Depressurization time |
From site level to 15250m in 10minutes |
||||||
Rapid decompression time |
75.2kPa~18.8kPa≦15s (Optional) |
||||||
Explosive decompression time |
75.2kPa~18.8kPa≦0.1s (Optional) |
||||||
Temperature |
Temperature range |
Low temperature range: A:0℃; B: -20℃; C:-40℃; D:-70℃ |
|||||
Temperature fluctuation |
±0.5℃ |
||||||
Temperature Rising/ |
Temperature rising approx:0.1~ 2.0℃/min; |
||||||
Temperature uniformity |
±1.5℃(-40.0℃∽100.0℃) |
||||||
±2.0℃(100.1℃~180.0℃or-40.0℃∽-70.0℃) |
|||||||
Humidity |
Humidity range |
20%RH~98%RH(work under atmos pheric humidity) |
|||||
Humidity fluctuation |
±2.0%RH |
||||||
Humidity uniformity |
≦±3.0%RH(humidity >75%R.H) |
||||||
Power |
AC380V 3phase 5lines 50/60Hz |
||||||
Aprroximate weight(kg) |
570 |
1000 |
1200 |
1300 |
2500 |
7500 |
|
Marked |
Other dimensions accept customize, |