Climatic Test Chamber for PV Modules Test: Thermal Cycling, Humidity-Freeze, and Damp-Heat test Chamber
Test 1. Thermal Cycling Test
Reference Standard: IEC 61215:2005 & Ed.3, IEC 61646:2008 ―TC200 thermal cycling test, TC50 thermal cycling test‖, and UL 1703-2012 ―temperature cycling test.
Test 2. Humidity-Freeze Test
Reference Standard: IEC 61215 Ed.3, IEC 61646:2008 ―humidity-freeze‖,UL 1703-2012―Humidity test
Test 3. Damp-Heat Test
Reference Standard: IEC 61215:2005 & Ed.3, IEC 61646:2008 ―damp-heat test
Thermal Cycling Test:
Designed for 50 and 200 thermal cycles, ranging from -40°C to +85°C, simulating rapid temperature changes to test material expansion, contraction, and durability under extreme temperature variations.
Humidity Freeze Test:
10 cycles of testing at +85°C & 85% RH, followed by rapid cooling to -40°C, replicating real-world scenarios like rapid cooling after high humidity and temperature exposure, ensuring modules can withstand freezing and thawing stress.
Damp Heat Test:
A comprehensive 1000-hour test at 85°C & 85% RH, simulating prolonged exposure to high heat and humidity, a key requirement for ensuring long-term reliability in harsh environments.
Check inquiry and get the catalogue to see the full standard configuration from JOEO Sales team.
Model | Environmental Test Chambers |
THC-80(A-F) | THC-150(A-F) | THC-225(A-F) | THC-408(A-F) | THC-800(A-F) | THC-1000(A-F) |
Internal Dimension (WxHxD mm) | 400x500x400 | 500x600x500 | 600x750x500 | 600x850x800 | 1000x1000x800 | 1000x1000x1000 | |
External Dimension (WxHxD mm) | 950x1450x1000 | 1050x1550x1050 | 1150x1900x1050 | 1200x1950x1350 | 1550x2000x1350 | 1550x2000x1550 | |
Humidity Range | 20% ~98%R.H. (10%~98% R.H./5% ~98% R.H,is a special optional condition,need Dehumidifier or Dryer) |
||||||
Temperature Range | Low Temperature : (A: 25℃; B: 0℃; C: -20℃; D: -40℃; E: -60℃; F:-70℃) High Temperature : 150℃( 200℃) |
||||||
Temperature Rising/ Falling Speed Rate |
Temperature rising/falling approx:0.1~ 3.33℃/min Linear control - for Test 2. Humidity-Freeze Test; Temperature rising/falling approx:0.3-1.66℃/min Linear control - for Test 1. Thermal Cycling Test ; |
||||||
Analytic Accuracy/ Distribution Uniformity of Temperature and Humidity |
0.1℃ ; 0.1% R.H ±2.0℃ ; ±3.0% R.H |
||||||
Control Accuracy/fluctuation of Temperature and Humidity |
±1.0℃ ; ±2.0% R.H ±0.5℃ ; ±2.0% R.H |
||||||
Optional Accessories | Inner door with operation Hole , Recorder, Water Purifier, Dehumidifier,Dryer etc | ||||||
Compressor | French "Tecumseh" Brand, Germany "Bitzer" Brand or samilar brand | ||||||
Power | AC220V; 1phase 3 lines ; 50/60HZ AC380V; 3phase 5 lines ; 50/60HZ |
||||||
Approx. Weight (Kg) | 150 | 180 | 250 | 380 | 560 | 700 |