Temperature Humidity And Vibration Test Chamber

Temperature Humidity And Vibration Test Chamber

IEC 68-2-1(GB2423.1-2008)
IEC 68-2-2 (GB2423.2-2008)
IEC 68-2-3(GB2423.3-2006)
IEC 68-2-30(GB2423.4-2008)
IEC 68-2-14(GB2423.22-2008)
MIL-STD-810D (GJB150.3A-2009)
MIL-STD-810D (GJB150.4A-2009)
MIL-STD-810D (GJB150.9A-2009)

Description

 Temperature Humidity And Vibration Test Chamber


Application

Temperature humidity and vibration test chamber with suitable vibration test bench can meet the requirements of temperature, humidity and vibration test. The three integrated test system has been widely used in aviation, aerospace, ship, electrical, electronic, communication and other fields.

Feature

  • The insulation material is fireproof and high strength PU polyurethane foam insulation material.

  • High precision perfect appearance design, the external use of double-sided cold rolled plate electrostatic powder coating material, the internal use of SUS#304 high temperature stainless steel.

  • The control system and control circuit components are made of well-known brands.

  • The introduction of Japan, Germany advanced refrigerator control technology, energy saving more than 20%.

Control System or Oscillator Required:
In addition to the compact vibration generator and power amplifier unit, a vibration control system or function generator, accelerometer and charge amplifier may be required for your application. An optional oscillator is available for the power amplifier unit. As for details, please contact our sales department.

Main Technical Parameter for Temperature Test Chamber

 

 

 

 

 

 

 

Model

Agree Chamber

VTH-408-(A-F)

VTH-1000-(A-F)

VTH-1200-(A-F)

VTH-3000-(A-F)

VTH-5000-(A-F)

VTH-6000-(A-F)

VTH-9000-(A-F)

VTH-10000-(A-F)

VTH-15000-(A-F)

VTH-20000-(A-F)

VTH-25000-(A-F)

VTH-30000-(A-F)

Capacity(L)

500

1200

2000

3000

5000

6000

9000

10,000

15,000

20,000

25,000

30,000

Working space Internal Dimension WxHxD (mm)

800x800x800

1050x1000x1150

1200x1200x1400

1400x1350x1600

1600x1600x1800

1900x1600x2200

2000x2000x2300

2200x2000x2600

2600x2000x3000

2000x3000x3300

3000x2500x3300

3000x3000x3300

Without Vibration Tester's Height External Dimension WxHxD(mm) 

1950x1900x3950

2250x2100x4350

2120x2150x4500

2300x2000x5350

2300x2280x5350

2900x2300x5500

2400x2600x6620
 or
3060x2900x5500

2600x2650x6300
 or
3260x2900x5800

3000x2650x6900
 or
3660x2900x6400

4060x6700x2900

4060x3400x6700

4060x3900x6700

Dimension of Vibration Shaker's Table

300x300

600x600

800x800

1000x1000

1200x1200

1500x1500

1600x1600

1800x1800

2500x2500

2500x2500

2500x2500

2500x2500

Temperature Range

High Temperature : 150℃( 200℃)
Low Temperature : ( A: 25℃; B: 0℃; C: -20℃; D: -40℃;E: -60℃; F:-70℃)

Humidity Range

20% ~98%R.H.
(10%~98% R.H./5% ~98% R.H,is a special optional condition,need Dehumidifier)

Analytic Accuracy/
Distribution Uniformity
of Temperature and Humidity

0.1℃ ; 0.1% R.H
±0.2℃ ; ±0.3% R.H

Control Accuracy of Temperature

±0.5℃ ; ±2.5% R.H

Temperature Rising/
Falling Speed Rate

Temperature rising approx:0.1~3.0℃/min;Temperature falling approx:0.1~1.2℃/min
(optional for 5℃/min, 10℃/min,15℃/min, 20℃/min,25℃/min Rising/Falling Speed Rate with average control or Linear average control)

Cooling System

Wind cooling or water cooling/single segment compressor
(-40℃, double segment compressor -70℃)

Optional Accessories

Inner door with operation Hole , Recorder, Water Purifier, Dehumidifier

Vibration Test Equipment

Choose Vibration tester according to customer' s test condition,
please take Vibration Test system' s  catalog for reference

Structural Style

L-Elevator ,G -Gantry elevator , F-Fixture type

Power

AC380V,3 phase 5 lines,50/60HZ


Technical Parameters for Vibrstion Sharker

 

 

 

 

 

 

 

 

 

 

 

 

 

System Model

Sine/Random Force (kN)

Shock Force(kN)

Frequency Range (Sine) (Hz)

Frequency Range (Random)(Hz)

Max. Acceleration (Sine) (g)

Max. Acceleration (Random) (g)

Max. Velocity  (m/s)

Max. Displacement (mm)

Max. Load (kg)

Moving Part Mass (kg)

Armature Diameter (mm)

Resonance Point  (Hz)

Isolation Airbag Resonance Frequency (Hz)

Weight (kg)

ES-1-150

 1/1

2

3-4500

3-4500

50

30

2

25

70

2

Φ150

3900

3

395

ES-2-150

 2/2

4

3-4500

3-4500

100

60

2

40

70

2

Φ150

3900

3

395

ES-3-150

 3/3

6

3-3500

3-3500

100

60

2

25

120

3

Φ150

2900

3

480

ES-6-230

 6/6

12

3-3500

3-3500

100

60

2

51

300

6

Φ230

3400

3

590

ES-10-240

 10/10

20

3-3200

3-3200

100

60

2

51

300

10

Φ240

2700

2.5

900

ES-10G-240

 10/10

20

3-3000

3-3000

85

50

2

76

300

13

Φ240

2500

2.5

1000

ES-10H-240

 10/10

20

3-3000

3-3000

100

60

2

51

300

10

Φ240

3300

2.5

900

ES-20-320

20/20

40

3-3000

3-3000

100

60

2

51

300

20

Φ320

2800

2.5

1700

ES-20G-340

20/20

40

3-3000

3-3000

80

48

2

76

300

25

Φ340

2700

2.5

1700

ES-30-370

30/30

60

3-2800

3-2800

100

60

2

51

500

30

Φ370

2500

2.5

2490

ES-40-370

40/40

80

3-2800

3-2800

130

78

2

51

500

40

Φ370

2500

2.5

2490

ES-30G-370

30/30

60

3-2600

3-2600

85

51

2.4

100

500

35

Φ370

2400

2.5

2540

ES-40G-370

40/40

80

3-2600

3-2600

100

60

2.4

100

500

35

Φ370

2400

2.5

2540

ES-40-445

40/40

80

3-2700

3-2700

80

48

2

51

800

50

Φ445

2400

2.5

4500

ES-50-445

50/50

100

3-2700

3-2700

100

60

2

51

800

50

Φ445

2400

2.5

4500

ES-60-445

60/60

120

3-2700

3-2700

100

60

2

51

800

50

Φ445

2400

2.5

4500

ES-50G-445

50/50

100

3-2600

3-2600

90

54

2

76

800

55

Φ445

2300

2.5

4500

ES-60G-445

60/60

120

3-2600

3-2600

100

60

2

76

800

55

Φ445

2300

2.5

4500

ES-50G-445

50/50

100

3-2500

3-2500

85

51

2

100

800

60

Φ445

2200

2.5

4500

ES-60G-445

60/60

120

3-2500

3-2500

100

60

2

100

800

60

Φ445

2200

2.5

4500

ES-70G-480

70/70

140

3-2700

3-2700

100

60

2

76

1000

70

Φ480

2200

2.5

4500


About the Bench tables ,please contact with us our Sales Team to get more details, Inquiry Now!