Description
Introduction
JOEO IPX56 Water Spray Test Chamber requires the distance between the nozzle and the measured object to be 2.5-3 meters, so when the external pipe is connected, the rain spray test chamber has four outward directions, namely, back, up, left, and right. The direction of the external interface depends on the customer's on-site requirements. If you have a spacious field with a top height of more than 3 meters, you can use a four-way connection.
If your site is limited, you cannot use all four directions. If the walls of two adjoining rooms can be opened, the open walls can be placed in the other room, and the entrance to the site needs to be made accessible.
Features
- Equipped with a standard universal wheel.
- Rain test chambers with water tank, water circulation, no need to build another waterproof laboratory.
- Made of SUS304 stainless steel, Shell is painted, beautiful and durable
- Standard test door, Equipped with a large observation window of 400*300mm.
- Two ways for the nozzle of the water spray chamber, one is fixed on the nozzle, mechanically fixed, and does not require human hands.
- Turntable is made of SUS304 stainless steel material.
Model |
Internal Dimension
WxHxD (mm) |
External Dimension
WxHxD (mm) |
IPX56S-500 |
800x800x800mm |
3600x780x1600mm |
IPX56S-700 |
900x900x900mm |
3800x980x1750mm |
IPX56S-1000 |
1000x1000x1000mm |
3900x1080x1750mm |
IPX56S-1700 |
1200x1200x1200mm |
4000x1180x1850mm |
IPX56S-1900 |
1200x1200x1300mm |
4200x1380x1850mm |
Orifice diameter IPX5 |
φ6.3mm |
Orifice diameter IPX6 |
φ12.5mm |
Flow IPX5 |
12.5±0.625 (L/min) |
Flow IPX6 |
100±5 (L/min ) |
Load-bearing |
100KG |
Turntable height |
100mm |
Flow control mode |
Manual adjustment (rotor flow meter) |
Safety protection measures |
Leakage protection, water shortage protection,
short circuit protectio |
Power |
AC 220V |
Standard
GB/T 4208-2017 Protection class of enclosure (IP code)
GB/T 2421.1-2008 Environmental Testing of Electrical and Electronic Products - Overview and Guidelines
GB/T 2423.37-2006 Environmental testing of electrical and electronic products - Part 2: Test methods Test L: Sand and dust test
IEC 60529:2013. IDT
IEC 60068-1:1988. IDT
IEC 60050-195:1998 International Electrotechnical Terminology Part 195: Earthing and Protection against Electric Shock
IEC 60050(826):1982 International Electrotechnical Terminology Chapter 826: Electrical installations in buildings
IEC 60071-2:1996 Insulation coordination - Part 2: Guidelines for use